ブックタイトルTASCO CATALOG 2015

ページ
18/56

このページは TASCO CATALOG 2015 の電子ブックに掲載されている18ページの概要です。
秒後に電子ブックの対象ページへ移動します。
「ブックを開く」ボタンをクリックすると今すぐブックを開きます。

概要

TASCO CATALOG 2015

REFRIGERATION CYCLE CLEANERSUsed to clean the existing pipes and the system when replacing the compressor.TA353-400TA353-800Refrigeration Cycle Cleaners (4.0l/8.0l Types)Item no.ApplicationPower SupplyMotorDischarge PressureDischarge CapacityPump ShapeDetergentTank VolumeAccessoryOuter DimensionsWeightTA353-400Packaged A/C220V200WMAX=1.5MPa(15kg/cm 2)4.0l/min 240l/hrTwo-cylinderR225,Solve 5512lCleaning hose 150cm×3305W×443D×540H mm43kgTA353-800Large-sized system (e.g., GHP)220V400WMAX=2.0MPa(20kg/cm 2)8.0l/min 480l/hrTwo-cylinder×2R225,Solve 5527lCleaning hose 150cm(1/4″×1, 3/8″×2)500W×420D×700H mm55kgNecessity of Cycle CleaningCase 1Case 2When you replace a burntcompressor,When you replace an A/C orrefrigeration system byutilizing the existing pipes,Impurities,deterioratedoil,metal scrap, and swarfwill remain in the systemand the connection pipes.There will be a high possibilityof impurities and deterioratedoil having adhered to theinside of the pipes.If the system keepsbeing used further, therewill be a high possibilityof clogging the capillarytubes and breaking thecompressor to causesystem damage.You need to clean thesystem and the pipes.Example Connection & PartsFill the pipes with a detergentand circulate it to clean the system.Remove such replacementparts as compressors and dryers.N2 connection fordetergent dischargeReturnconnection valveDischargevalve connectionWhen cleaning is completed, purge the residual detergent out of the pipesby using N2 nitrogen.Then dry the pipes by using a vacuum pump.D ETERGEN TDischargepressuregaugeMain switchSuctionpressuregaugeFilterTransparentstrainerChange the detergent untilit becomes transparent.You can easilysee the degree towhich thedetergent is dirty.Use the HCFC-group R225detergent. At present, thereis no effective alternativedetergent.Recover the used detergentand ask the specialists torecycle or demolish it.Bypass Passage for Refrigeration Cycle Cleaner(for TA353-400)◆◆◆◆◆◆◆◆◆Item no. TA353-400B1.5m Hose 1/4 Flare x 1/4 Flare with Valve x 2Packless Valve 1/4 Flare x 1Connector 1/4 Male Flare x 1/4 Male Flare x 2Connector 1/4 Male Flare x 3/8 Male Flare x 2Connector 1/4 Male Flare x 1/2 Male Flare x 2Connector 1/2 Feale Flare x 5/8 Male Flare x 2Connector 5/8 Feale Flare x 3/4 Male Flare x 2A must item for Refrigeration Cycle CleanerCleaning each pipe of refrigerant circulationwithout indoor equipmentBypass Passage for Refrigeration Cycle Cleaner(for TA353-800)◆◆◆◆◆◆◆◆◆Item no. TA353-800B1.5m Hose 3/8 Flare x 3/8 Flare with Valve x 2Packless Valve 3/8 Flare x 1Connector 1/4 Male Flare x 3/8 Male Flare x 2Connector 3/8 Male Flare x 3/8 Male Flare x 2Connector 3/8 Male Flare x 1/2 Male Flare x 2Connector 1/2 Feale Flare x 5/8 Male Flare x 2Connector 5/8 Feale Flare x 3/4 Male Flare x 2A must item for Refrigeration Cycle CleanerCleaning each pipe of refrigerant circulationwithout indoor equipment15