ブックタイトルTASCO CATALOG 2015

ページ
46/56

このページは TASCO CATALOG 2015 の電子ブックに掲載されている46ページの概要です。
秒後に電子ブックの対象ページへ移動します。
「ブックを開く」ボタンをクリックすると今すぐブックを開きます。

概要

TASCO CATALOG 2015

INFORMATION RELATED TO THE NEW REFRIGERANTSHCFC Regulation Schedule Proposed by the Montreal Protocol (*)(%)100HCFC100%(Revised in 1995)8065%60402035%10%0.5%Regulation Amended in 1995Based on the 1989 performanceJanuary 1st, 1996 or later100% or less (5,563 ODP ton)January 1st, 2004 or later65% or lessJanuary 1st, 2010 or later35% or lessJanuary 1st, 2015 or later10% or lessJanuary 1st, 2020 or laterAbolished (However, the refill refrigerant for the air conditioning andrefrigeration systems will be an exception for another 10 years.)Characteristics of CFC, HCFC, HFC and Blended Refrigerants (*)CFCHCFCHFCBlendedRefrigerantsHydrocarbonsAmmoniaNo.R11R12R502R123R124R22R23R32R125R134aR143aR404AR407AR407CR407ER410AR507AR290R600aR71701990 96 2000 04 10 15 20 25 30(Year)ComponentーーR22/115ーーーーーーーーR125/143a/134aR32/125/134aR32/125/134aR32/125/134aR32/125R125/143aPropaneIsobutaneーCompositionーー48.8/51.2ーーーーーーーー44/52/420/40/4023/25/5225/15/6050/5050/50ーーーBoilingPoint23.8-29.8-45.427.7-11.9-40.8-82.1-51.7-48.1-26.3-47.2-46.5-45.5-43.6-42.9-51.4-46.7-42.1-11.7-33.343Life in theAtmosphereWt%℃Year50102ー1.45.913.32645.632.614.648.3ーーーーーーSeveralmonthsSeveralweeks14ODPNote 11.01.00.3340.020.0220.05500000000000000*The percentage of consumption is based on ODP ton.GWPNote 24,0008,5005,600934801,70011,7006502,8001,3003,8003,2601,7701,5301,3601,7303,300<3<3<1AllowableConcentrationppm***1,0001,0001,00010~301,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,0001,00025Combustibleness*Incombustible(AI)Incombustible(AI)Incombustible(AI)Incombustible(BI)Incombustible(AI)Incombustible(AI)Incombustible(AI)Combustible(A2)Incombustible(AI)Incombustible(AI)Combustible(A2)Incombustible(AI/AI)Incombustible(AI/AI)Incombustible(AI/AI)Incombustible(AI/AI)Incombustible(AI/AI)Incombustible(AI/AI)Combustible(A3)Combustible(A3)Combustible(B2)*ASHRAE34, **IPCC-1995 (Integration period: 100 years), ***ACGIH, WEEL, and others.Note 1: ODP=Ozone Depletion Potential...the coefficient which indicates the extent to which a particular refrigerant destroys the ozone layer. It is also thevalue, supposing CFC-11=1.0, which indicates the extent to which the ozone layer is affected by a particular gas of the same mass which has been dischargedinto the atmosphere.Note 2: GWP=Global Warming Potential...the coefficient, defined on a carbon dioxide weight basis, which is calculated by expressing integration periodswith 100-year values.30